BJMBJ - TYPE II WALKWAY LT. GULL GRAY G-8128

  • MSDS: BJMBJ
  • Manufacturer: AKRON PAINT AND VARNISH INC
  • Product Name: TYPE II WALKWAY LT. GULL GRAY G-8128
  • National Stock Number: 8010-00-141-7842
Product Identification

Product ID:TYPE II WALKWAY LT. GULL GRAY G-8128
MSDS Date:04/10/1995
FSC:8010
NIIN:00-141-7842
MSDS Number: BJMBJ

Responsible Party
AKRON PAINT AND VARNISH INC
1390 FIRESTONE PARKWAY
AKRON, OH 44301-1624
US

Emergency Phone: 216-773-8911

Info Phone: 216-773-8911

Cage: 70228

Contractor
AKRON PAINT AND VARNISH INC
AKRON, OH 44301-1624 US

Telephone: 216-773-8911

Cage: 70228

Ingredients

ALIPHATIC PETR.DISTILLATES (VP 15 MMHG) (SARA 313) <8%

CAS: 8030-30-6

RTECS: DE3030000

Fraction By Weight: 20-50%

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM


SILICA, CRYSTALLINE - QUARTZ

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: 20-50%

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.1 MG/M3 RDUST;9293

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:IF SWALLOWED: ASPIRATION OF MATERIAL
INTO THE LUNGS CAN CAUSE CHEMICAL PNEUMONITIES WHICH CAN BE FATAL.
Explanation of Carcinogenicity:THERE IS LIMITED EVIDENCE OF
CARCINOGENICITY OF CRYSTALLINE SILICA TO HUMANS, IARC CLASS 2A.
Effects of Overexposure:EYES:CAN CAUSE REDNESS, IRRIT, SWELLING &
BLURRED VISION. SKIN:PROLONGED/REPEATED CONTACT CAN CAUSE MODERATE
IRRIT, DEFATT, DERMATITIS. EXCESSIVE INHALE:POSSIBLE RESPIRATORY
IRRIT, DIZZINESS, WEAKNESS , FATIGUE, NAUSEA, HEADACHE, UNCONSCOUS&
EVEN ASPHYXIATION. SWALLOWED:GASTROINTESTINAL IRRIT, NAUSEA, VOMIT,
DIARRHEA.

First Aid

First Aid:EYES:FLUSH W/LG AMTS OF WATER FOR 15 MINS, LIFTING LIDS, GET
PROMPT MED ATTN. SKIN:WASH THORO W/SOAP & WATER, REMOVE CONTAM
CLOTHES PROMPTLY, WASH BEFORE REUSE. CONSULT DR IF IRRIT PERSISTS.
SWALLOW:D O NOT INDUCE VOMIT. KEEP PERSON WARM/QUIET & GET MED
ATTN. IF ASPIRATION:DRINK 1-2 GLASSES OF WATER TO DILUTE.
INHALE:MOVE PERSON TO FRESH AIR. ADMIN OXYGEN/CPR AS NEEDED. KEEP
WARM/QUIET. GET MED.

Fire Fighting

Flash Point Method:TCC
Flash Point:50 F/10 C
Lower Limits:0.9
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER. USE
WATER FOR COOLING MATERIAL STORED IN VICINITY OF FIRE.
Fire Fighting Procedures:USE SCBA W/FULL FACEPIECE OPERATED IN
PRESSURE-DEMAND OR OTHER POSITIVE PRESSURE MODE. WEAR PROTECTIVE
CLOTHING. APPLY TO HOT SURFACE REQUIRES SPECIAL CAUTIONS.
Unusual Fire/Explosion Hazard:VAPOR > THAN AIR MAY TRAVEL TO DISTANT
IGNITE SOURCES. NEVER USE TORCH ON/NEAR EMPTY CONTAINER, MAY
EXPLODE.OVEREXP TO DECOMP MAY CAUSE DELAYED HEALTH HAZARDS.

Accidental Release

Spill Release Procedures:SM:ABSORB LIQ W/RAGS,ABSORB,VERMICUL,OTHER &
TRANSFER TO HOOD. LG:ELIM IGNITE SOURCES & DIKE AREA, VENT INDOOR
AREA, PUMP LIQ INTO SALVAGE TANK, TAKE-UP REMAINING LIQ W/SAND,
OTHER & SHOVEL INTO CONTA INER. PREVENT RUN-OFF TO SEWERS & BODIES
OF WATER*
Neutralizing Agent:N/K. *NOTIFY AUTHORITIES AS REQUIRED BY LOCAL, STATE
& FEDERAL REGULATIONS.

Handling

Handling and Storage Precautions:DO NOT DROP CONTAINER. AVOID
HEAT,SPARK & OPEN FLAME. STORE LG AMTS ONLY IN BLDG DESIGNED TO
COMPLY W/OSHA 1910.106. NEVER USE PRESSURE TO EMPTY.
Other Precautions:AVOID BREATHING SANDING DUST. HOT ORGANIC CHEMICAL
VAPORS/MISTS ARE SUSCEPTIBLE TO SUDDEN SPONTANEOUS COMBUSTION WHEN
MIXED WITH AIR. IGNITION MAY OCCUR AT TEMPS BELOW THOSE PUBLISHED
IN LITERATURE AS "AUTOIGNITION" OR "IGNITION" TEMPS.

Exposure Controls

Respiratory Protection:IF OUTDOOR OR OPEN AREAS WITH UNRESTRICTED
VENTILATION:APPROVED CHEMICAL/MECHANICAL FILTER DESIGNED TO REMOVE
A COMBINATION OF PARTICULATES & VAPOR. IN CONFINED AREAS, APPROVED
AIR LINE TYPE RESPIRATO RS OR HOODS.
Ventilation:SUFF VENT IN VOL/PATTERN TO KEEP AIR CONTAM CONCENTRATE
BELOW LIMITS & VOLATILES BELOW LIMITS. REMOVE DECOMP PRODUCTS.
Protective Gloves:WEAR RESISTANT GLOVES: NITRILE RUBBER.
Eye Protection:CHEM SPLASH GOGGLES, OTHER TYPE PERMITED
Other Protective Equipment:NORMAL PROTECTIVE CLOTHING. WASH
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
HEAVY SOVLENT VAPORS SHOULD BE REMOVED FROM LOWER LEVELS OF AREA & ALL
IGNITION SOURCES (NON-EXPLOSION PROF EQUIP) SHOULD BE ELIMINATED IF
FLAMMABLE MIX WILL BE ENCOUNTERED. REMOVE DECOMP PRODUCTS FOR MED
DURING WELDING OR FLAME CUTTING OF SURFACES COATED W/PRODUCT. FOR
BAKING FINISHES-VENT VAPORS EMITTED ON HEATING.

Chemical Properties

Boiling Pt:B.P. Text:240 TO 285F
Vapor Density:> THAN AIR
Spec Gravity:1.38
Evaporation Rate & Reference:6.84 X N-BUTYL ACETATE
Appearance and Odor:GULL GRAY LIQUID
Percent Volatiles by Volume:50.5

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZERS (E.G. NITRIC ACID)
Stability Condition to Avoid:KEEP AWAY FROM HEAT AND OPEN FLAMES.
Hazardous Decomposition Products:MAY FORM CARBON MONOXIDE AND DIOXIDE,
VARIOUS HYDROCARBONS, ETC.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.